Common vulnerabilities and Exposures (CVE)

Skip to main content

Required CVE Record Information

Description

In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.

CVSS 1 Total

ScoreSeverityVersionVector String
2.8LOW3.0CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N

Product Status

Learn more

Versions 1 Total

Default Status: unknown

affected

Updated:

This container includes required additional information provided by the CVE Program for this vulnerability.